19.12.2006
VI TELEFILTER
Measurement condition
Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 C dBm
Filter specification
TFS 456Y
1/5
460 || -5,6 pF 460 || -5,5 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 456Y is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The nominal frequency fN is fixed at 456,0 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
Insertion loss (reference level) Nominal frequency Passband Pass band ripple Relative attenuation fN fN fN 4,6 20,0 ... fN MHz ... fN MHz ... fN 2,3 20,0 50,0 p-p arel MHz MHz MHz
ae = amin
typ. value
10,0 0,25 dB dB
tolerance / limit
max. 13,7 456,0 fN 2,3 max. 1 dB MHz MHz dB
fN PB
0,5 45 54 85 20
dB dB dB ns dB
max. min. min. max. min. max.
1 40 48 200 10 10
dB dB dB ns dB dBm
Group delay ripple within PB Return loss within PB Input power level Operating temperature range Storage temperature range Frequency inversion temperature Temperature coefficient of frequency TCf ** OTR
31 -0,04 C ppm/K
2
- 45 C ... + 85C - 45 C ... + 85C -
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) f(Hz) = TCf(ppm/K2) x (T-T0)2 x fcat(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 456y.doc
Version 1.1
19.12.2006
VI TELEFILTER
Filter characteristic
0
Filter specification
TFS 456Y
2/5
0
1.92
-7
-1
1.77
-14
-2
1.62
-21
-3
1.47
magnitude in dB
magnitude in dB
-28
-4
1.32 delay in s
-35
-5
1.17
-42
-6
1.02
-49
-7
0.87
-56
-8
0.72
-63
-9
0.57
-70 356
376
396
416
436
456 476 frequency in MHz
496
516
536
556
-10 453
453.6
454.2
454.8
455.4 456 456.6 frequency in MHz
457.2
457.8
458.4
0.42 459
Construction and pin connection
(All dimensions in mm) 1 2 3 4 5 6 7 8 9 10 Ground Ground Ground Output Output Ground Ground Ground Input Input
S 456Y U51
Date code
Date code: U V W ...
Year + week 2006 2007 2008
50 Test circuit
9
L1 C1 L2
5
10
SAW
L3 C2 L4
4
1, 2, 3, 6, 7, 8
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 456y.doc
Version 1.1
19.12.2006
VI TELEFILTER
Stability characteristics, reliability
Filter specification
TFS 456Y
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer:
Pull Off Direction
3000 min. 300 mm min. 500 mm min. 300 mm
Tape (all dimensions in mm) W : 16,00 0,3 Po : 4,00 0,1 Do : 1,50 +0,1/-0 E : 1,75 0,1 F : 7,50 0,1 G(min) : 0,60 P2 : 2,00 0,1 P1 : 8,00 0,1 D1(min) : 1,50 Ao : 5,50 0,1 Bo : 7,50 0,1 Ct : 13,5 0,1
P1 Date Code t Do Po P2
E G Ct Bo F
Ko
Typ
PIN Marker
D1
Ao
W2
Reel (all dimensions in mm) A : 330 W1 : 16,4 +2/-0 W2(max) : 22,4 N(min) : 50 C : 13,0 +0,5/-0,2
A
C N
W1
The minimum bending radius is 45 mm.
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
G
W
Filename: tfs 456y.doc
Version 1.1
19.12.2006
VI TELEFILTER
Air reflow temperature conditions
Filter specification
TFS 456Y
4/5
Conditions Average ramp-up rate (30C to 217C) > 100C > 150C > 217C Peak temperature Time within 5C of actual peak temperature Cool-down rate (Peak to 50C) Time from 30C to Peak temperature
Exposure less than 3C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260C between 10 and 30 seconds less than 6C/second no greater than 300 seconds
Chip-mount air reflow profile Temperature / C
max. 260C
217C
max. 300 s
10 ... 30 s 30 ... 150 s
Time / s
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 456y.doc
Version 1.1
19.12.2006
VI TELEFILTER
History Version
1.0 1.1
Filter specification
TFS 456Y
5/5
Reason of Changes
- development specification generated - add of terminating impedances, typical values and filter characteristics
Name Pfeiffer Pfeiffer
Date 30.10.2006 19.12.2006
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS456Y

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X